Version 2.01 December 13, 2024
  • Fixed a bug that an invalid byte of data was output at the end of test data in ASYNC simulation.
    * Version 2.00 only. This does not apply to versions earlier than Version 2.00.
Version 2.00 December 5, 2024
  • In HDLC simulation, the problem that flags were not output correctly when Idle mode was set to Flag.
  • Integrated with firmware for LE-3500XR(V2)/LE-2500XR(V2)
    * LE-3500XR(V2)/LE-2500XR(V2) product release version.
    * Models without (V2) will not be updated to (V2) models.
Version 1.05 March 27, 2023
  • Added text conversion/printing function for measurement data.
  • Added screenshot printing function.
  • Improved to operate the pull-up menu on the data display screen with [SHIFT] + [MENU].
  • Changed the default display code to JIS when Data code: JIS and Data bit: 7.
  • Fixed a minor bug in timestamp diff display in frame view.
  • Fixed a minor bug in MODBUS and HDLC(LAPD) translation display.
  • Fixed a bug that the TOP and END keys do not work on the TREND data display screen.
Version 1.04 March 1, 2022
  • Increased communication speed to 3.150Mbps (LE-3500XR) /1.544Mbps (LE-2500XR)
  • Speed up the sampling clock of the logic analyzer function to a maximum of 50MHz
  • Fixed a bug that the logic analyzer trigger setting for the CTS signal does not work when TTL is selected.
  • Fixed a bug that the RT LED may light up when RS-422/485 is selected.
  • Fixed a bug that the address filter setting 80h to FFh does not work when HDLC is set.
  • Fixed a bug that CLK of twice the communication speed which set at configuration is output during SPI simulation.
  • Fixed to be able to specify the start/stop condition for the trigger character at I2C.
  • Fixed a minor bug of the I2C master simulation.
  • Fixed a bug that the setting of Frame end time does not work at Burst.
  • Fixed a minor bug in the autorun function.
  • Fixed a minor bug in the English display.
Version 1.03 November 30, 2021
  • Change of touch panel internal processing
Version 1.02 February 24, 2021
  • Fixed a bug that depending on the situation it redundantly sends data to the PC in remote monitoring by LE-PC300R.
Version 1.01 July 16, 2020
  • Supports reading of measurement data of high-speed HDLC/SPI communication firmware "OP-FW10XR".
  • Improved so that the time stamp can be switched to the differential time display in the translation display and line feed display.
  • Fixed the problem that SPI clock polarity/clock phase setting is not reflected correctly.
  • Fixed minor bugs of SEND, WAIT, and DISI commands in PROGRAM simulation.
  • Fixed a minor bug in the automatic backup process to SRAM.
  • Corrected the initial state to high impedance when Manual is set for RS-422/485 driver control.
  • Other minor bugs in display and file processing have been fixed.
Version 1.00 April 17, 2020
  • First public version