PRODUCT
Expansion kit for LAN/PoE (2ch) measurement (EtherCAT supported)
(For LE-8600X/LE-8500X series)
(For LE-8600X/LE-8500X series)
SB-FE2
Specification
Applicable analyzers | LE-8600X series, LE-8500X series |
---|---|
Measurement interface | RJ-45 connector Ports A, B, C, D: 100BASE-TX/10BASE-T Through connection tap specification between ports A-B and C-D※1 |
Online monitor function | 2-channel simultaneous recording and real-time display of LAN frames flowing between ports A-B and C-D |
Suitable frame size | 60 bytes to 9KB |
Time stamp | The reception time is added as time stamp data for each received frame Resolution: 8n seconds/1u seconds/10u seconds can be selected |
Detailed translation | Target protocols: IPv4, ARP, ICMP, TCP, UDP, DHCP, EtherCAT, IPv6, ICMPv6 |
pcap conversion | Measurement data can be converted to a pcapng format file and saved |
csv conversion | Measurement data can be output as a csv format file |
txt conversion | Measured data can be output as a txt file |
Filter function | Can monitor only specific frames that match one or two specified conditions |
Trigger function | Condition: When a specified frame is received or when an external TTL signal changes Operation: Automatically stops monitoring, counts the number of times the condition is met, and outputs an external TTL signal |
Search function | Can search for, cue, and count only specific frames that match the specified conditions from the measured data |
Delay time measurement function | Tx between specified ports or Rx, measures the time difference between the two reception timings in µsecond units, and displays the current, maximum, minimum, and average values as delay times |
Statistical analysis function | Two frame counter values are collected at specified intervals (2 to 240 seconds, 1 to 240 minutes) and displayed as graphs, and all frame counter values and data rates can be displayed in real time |
PoE measurement function | Supports PoE/PoE+/PoE++ (IEEE802.3af/at/bt), and can measure simultaneously with LAN frames Recording interval: 1ms to 1s, Maximum number of records: 16.77 million, Voltage measurement range: 0 to 60V (Accuracy: ± 1% F.S.), Current measurement range: 0 to ± 900mA (Accuracy: ± 1% F.S.) |
Packet differential measurement function | Compares received packets between specified ports and displays the differences |
Other functions | Auto-save function, automatic backup function, time-specified automatic RUN/STOP function, file management function, printout function |
Components | Interface sub board x 1, LAN cables x 2, external signal output cable (LE-4TG) x 1, quick start guide x 1, warranty card x 1 |
*1: The connection remains even when the power is off.