Can I record the data automatically without any data loss?
It depends on the type of the connection.
In case of USB connection
You can record the data without any data loss.
In case of serial connection
It depends on monitoring conditions of your analyzers, or capacity and loading conditions of your PC. Following is the standard of the monitoring conditions.
< Conditions >
*Data size of one flame: 1K byte
*PC: Pentium4 1.5GHz Windows2000 115.2kbps
Protocol | Communication Type | Error Check (BCC/FCS) | Idol | Speed |
---|---|---|---|---|
ASYNC | half-duplex | No | No | 38400bps |
full-duplex | No | No | 24000bps | |
half-duplex | Yes | No | 38400bps | |
full-duplex | Yes | No | 24000bps | |
half-duplex | No | 10ms | 38400bps | |
full-duplex | No | 10ms | 19200bps | |
half-duplex | Yes | 10ms | 38400bps | |
full-duplex | Yes | 10ms | 24000bps | |
HDLC | half-duplex | No | No | 33600bps |
full-duplex | No | No | 19200bps | |
half-duplex | Yes | No | 33600bps | |
full-duplex | Yes | No | 19200bps | |
half-duplex | No | 10ms | 33600bps | |
full-duplex | No | 10ms | 19200bps | |
half-duplex | Yes | 10ms | 33600bps | |
full-duplex | Yes | 10ms | 19200bps | |
SYNC | half-duplex | No | No | 33600bps |
full-duplex | No | No | 16800bps | |
half-duplex | Yes | No | 33600bps | |
full-duplex | Yes | No | 16800bps | |
half-duplex | No | 10ms | 33600bps | |
full-duplex | No | 10ms | 16800bps | |
half-duplex | Yes | 10ms | 33600bps | |
full-duplex | Yes | 10ms | 16800bps |