GUIDE

Mar. 6, 2015
LINEEYE CO., LTD.

Guide on Updating the Firmware of LE-3500/2500/1500 (version 1.11)

Thank you for using LINEEYE products.
LINEEYE has released the latest firmware (ver1.11) of LE-3500/2500/1500.
If you have been using the ex-version, please update to the latest version.

[ Update Information ]

  1. Number of pre-registered data tables are increased to 160.(before 16 tables)
    The former version has only 16 kinds (0 to F) simulation data tables.
    The latest version has 160 kinds (00 to 9F) and has upper group (0 to 9F) and lower group (0 to F)
    For example, "table group 0" has table 00 to 0F, and "table group 1" has table 10 to 1F.
    < Table Summary (former) >
    < Table Summary (new) >
    Select the table number from [0] to [F] key. Initial setting is Group0. To change the Group, go to the data table summary and select the Group by [0] to [F] key.
  2. Improves the each modes of simulation function.
    MANUAL simulation
    Able to send 160 kinds of pre-registered data.
    Press [Shift]+[<]/[>] to change the table group.
    Then, press [0] to [F] key to send the pre-registered data corresponding to the each key.
    "Table group 0" is selected as initial setting.
    If selecting "Send" as a trigger action, table "00" to "9F" can be selected.
    < Screen while monitoring >
    FLOW simulation
    Able to send 160 kinds of pre-registered data.
    POLLING simulation
    Able to send only 0 to F table.
    The table number 10 to 9F are not available.
    PROGRAM simulation
    Able to send 160 kinds of pre-registered data in the commands of "SEND TBL", "SEND FRM" and "IF TBL".
    Also, a parameter is added to specify the table group in the commands of "SEND REG" and "SEND KEY".
    In the case of "SEND REG" command, it is able to specify the transmission table directly by selecting register value (0 to 159) without setting the parameter of table group (Don't care).
    < PROGRAM mode setting >
    < PROGRAM mode setting >
  3. Able to set maximum 2 characters as frame end of ASYCN
    Able to set one or two characters as the frame end for ASYNC communications.
    It enables to realize the accurate frame if using with the setting of idle time for frame end.
    Furthermore, it enables to set "displaying each frame in another line" and have the time stamp on the top of the frame.
    < Setting screen >
    when setting "FRM END:10 03."
    The analyzer realizes the frame end when receiving idle time for more than 5ms, or receiving "10h, 03h".
  4. Prohibits Simulation and BERT function
    Some customers only use the analyzer to monitor data for on-site tests and do not want to perform the
    simulation or BERT functions by accident.
    < Setting screen >
    Press [Menu]->[3]-[6] and set "SIM LOCK:ON" to prohibit simulation and BERT functions.
  5. Adds setting information of idle time and time stamp on the top of print-out data.
    Able to know the setting of idle time and time stamp on the top of print-out data.
    < Print-out data (former) >
    *=[LE-3500]=====[2015-03-05 14:50:07]=*
    * Model     : LE-3500                 *
    * Version   : 1.10                    *
    * Extension : Standard                *
    * Serial No.: ********                *
    * Start time: 2015-03-05 13:49:46     *
    * Stop time : 2015-03-05 13:53:55     *
    *-------------------------------------*
    * MONITOR DATA                        *
    *  PROTOCOL: PPP                      *
    *  S-SPEED : 57600   R-SPEED : 57600  *
    *  CODE    : ASCII   FCS     : FCS16  *
    *                 PRINT CODE : ASCII  *
    *=====================================*
    
    SD:41540D - - - - - -[ IDLE ]415426460D[ IDLE ] - - - - - -
        A TCR            [ 0029 ] A T & FCR[ 0007 ]
    RD: - - -0D0A4F4B0D0A         - - - - -        0D0A4F4B0D0A
             CRLF O KCRLF                          CRLF O KCRLF
    
    SD:[ IDLE ]4154453056315337353D305339353D343520264331264432
       [ 0022 ] A T E 0 V 1 S 7 5 = 0 S 9 5 = 4 5   & C 1 & D 2
    RD:        4154 -453056315337353D305339353D3435202643312644
                A T   E 0 V 1 S 7 5 = 0 S 9 5 = 4 5   & C 1 & D
    
    SD:53303D300D -[ IDLE ] - - - - - -[ IDLE ]415453373D353053
        S 0 = 0CR  [ 0002 ]            [ 0022 ] A T S 7 = 5 0 S
    RD:3253303D300D        0D0A4F4B0D0A         - - - - - - - -
        2 S 0 = 0CR        CRLF O KCRLF
    < Print-out data (new) >
    *=[LE-3500]=====[2015-03-05 15:24:07]=*
    * Model     : LE-3500                 *
    * Version   : 1.11                    *
    * Extension : Standard                *
    * Serial No.: ********                *
    * Start time: 2015-03-05 13:48:45     *
    * Stop time : 2015-03-05 13:53:55     *
    *-------------------------------------*
    * MONITOR DATA                        *
    *  PROTOCOL: PPP                      *
    *  S-SPEED : 57600   R-SPEED : 57600  *
    *  CODE    : ASCII   FCS     : FCS16  *
    *  IDLE TM : 1ms     TM STAMP: MS10m  *
    *                 PRINT CODE : ASCII  *
    *=====================================*
    
    SD:[ TMSP ] - - - - - - - - - - - - - -[ IDLE ][ TMSP ]4154
       [484553]                            [ 0025 ][484556] A T
    RD:        0D0A4E4F20434152524945520D0A                 - -
               CRLF N O   C A R R I E RCRLF
    
    SD:480D - - - - - -[ IDLE ]41540D - - - - - -[ IDLE ]415426
        HCR            [ 0029 ] A TCR            [ 0014 ] A T &
    RD: - -0D0A4F4B0D0A         - - -0D0A4F4B0D0A         - - -
           CRLF O KCRLF              CRLF O KCRLF
    
    SD:460D[ IDLE ] - - - - - -[ IDLE ]4154453056315337353D3053
        FCR[ 0007 ]            [ 0023 ] A T E 0 V 1 S 7 5 = 0 S
    RD: - -        0D0A4F4B0D0A        4154 -453056315337353D30
                   CRLF O KCRLF         A T   E 0 V 1 S 7 5 = 0
  6. Corrects the miner bug on remote monitor proceeding for USB connection.
    Corrects the bug that analyzer is still working as remote mode even though removing the USB cable and
    cannot go back to the stand-alone mode.

[Complete version history]

[ How to update the latest firmware ]

Please download the latest firmware from our Website.

Software for transferring firmware "LE8FIRM" is also available from our Website.

Refer to the"LE8FIRM.TXT" document in the utility CD and transfer the latest firmware to the analyzer.

[ Contact ]

Email: Contact Us