Add the character search in the search conditions.
The previous "Character search condition" is renamed as "Character (HEX) search condition".
Support Modbus protocol.
Record in another data files after appointed time.
Add the starting options.
-r "[name of configuration]"
After starting the LE-PC300G, selected analyzer which is set by the configuration starts measuring automatically. (able to set more than one units)
-q
Adjust the format of data files to enable to read the files immediately.
Increase the maximum block number (number of files) from 2000 to 2048.
Add SEND BRK command in the program editor. (when using with LE-3500)
Save the search conditions after closing the application.
Change the name of starting menu for On-line help as "LE-PC300G help".
Correct the minor bug of character input mode for data tables.
Display each communication frame in different line for ASYNC/SYNC protocol.
(Break signal of ASYNC is displayed as “?b”)
Display property of measured data. [file menu] -> [data property]
Add On-line Help
Add “Cut/Copy/Paste” functions in the transmission data table on Simulation feature.
Change the zoom switching display from combo box to track bar.
Pause the display of “Delay/ Flow/ Polling (master/slave)” while measuring.
Able to select data table number “0-9” by TEN key.
Add “50000, 200k, 417k” on I2C baud rate.
Change the icon of tool bar to full color.
Move the “Remote setting list” button next to “Remote setting” button.
Display the name of some icons by right clicking on tool bar.
Convert ASYNC measured data into CSV. Each frame is divided by time stamp.
Save text CSV conversion setting.
[Bug correction]
Correct the bug that some data with control lines is not converted into text properly.
Correct the bug that frame divided by time stamp is not outputted after CSV conversion.
Correct the bug that “excepting time stamp/ idle time” is not functioned properly. (Text conversion)
Correct the bug of PPP/ I2C/ SPI translation conversion when setting of “number of character: Max”. (Text conversion)
Correct the bug of CSV conversion ended in error after “receiving BERT result and conversion”.
Correct a minor bug of program editor in Program mode.
Correct a minor bug of HDLC X.25 packet translation display.
Correct a minor bug of IrLAP text conversion. “NS” and “NR” are displayed in opposite place.
In the test conversion of LAPD frame translation, “None” is displayed when the last bit of RD is “0”. In the previous version, “INFO” was displayed. (to be same as LE-8200)
Change the specification of “A1h” for EBCDIC and “7Fh”/ “BFh” for EBCDIK, to be same as LE-8200.