HOME > PRODUCT > LE-2500R
PRODUCT
Multi Protocol Analyzer

LE-2500R

●Supports UART, I2C, and SPI without option
●Multi-protocol supported
●Mega speed measurement
●Long time recording by AUTO SAVE function
●Logic analyzer analysis and signal voltage measurement
●Supports PC connection and remote control by Wi-Fi

LE-2500R: Japanese model (with Japanese manual)
LE-2500R-E: Abroad model (with English manual)

Specification
Specifications (Multi Protocol Analyzer LE-2500R-E)
Interface RS-232C (V. 24)
RS-422/485 (RS-530)*1
TTL(1.8V/2.5V/3.3V/5V level)
Expansion measurement interface*2 X. 20/21 [OP-SB10N + LE-25Y15]
RS-449 [OP-SB10N + LE-25Y37]
RS-530 [OP-SB10N]
V. 35 [OP-SB10N + LE-25M34]
TTL (USART) [OP-SB5GL]
Current loop [OP-1C]
CAN/LIN [OP-SB7GX]
Standard Protocol ASYNC (Asynchronous), ASYNC-PPP
Character synchronous SYNC/BSC
Bit synchronous HDLC/SDLC/X. 25
I2C, SPI
BURST*3
Optional Protocol CAN, Devicenet, LIN
Synchronous clock ST1 (DTE transmission clock), ST2 (DCE transmission clock), RT (DCE reception clock), AR (The synchronous clock extracted from the edge of the transmission and reception data)
Capture memory*4 DDR2-SDRAM 64MB
SRAM for automatic saving 512KB
Baud rate Full duplex: 1.000Mbps / Half duplex: 1.000Mbps
Speed setting range 50bps to 1.000Mbps Freely set to four effective digits, separately for transmission and reception.(Margin of error: ±0.01% or less)
Data format NRZ, NRZI, FM0, FM1
Data code ASCII, EBCDIC, JIS7, JIS8, Baudot, Transcode, IPARS, EBCD, EBCDIK, HEX
Character framing ASYNC : Data bit (5,6,7,8) + parity bit (0,1) + stop bit (1,2)
Character synchronous : Data bit + parity bit (6 or 8 bits in total)
Bit synchronous : Data bit (8 bits)
Parity bit NONE, ODD, EVEN, MARK, SPACE
Multi-processor bit MP (multiprocessor) bit is shown with a special mark.
Bit transmission order LSB first or MSB first (switchable)
Polarity inversion Normal or Inverted (switchable)
Error check For all protocols : Parity (ODD, EVEN, MARK, SPACE), Framing, Break, BCC (LRC, CRC-6, CRC-12, CRC-16, CRC-32, CRC-ITU-T).
BCC permeation mode.
For bit-oriented synchronous protocol : Abort, short frame
Online monitor function Communication log is recorded continuously and displayed in the LCD without affecting the communication lines.
Idle time display OFF (no record); Resolusion: 100ms, 10ms, 1ms; Max 999. 9 sec
Time stamp display The date and time when the communication data frame was sent and received are recorded. The time unit can be specified as OFF, day/hour/minute, hour/minute/second, minute/second/10ms.
* When set to EXTEND:ON, the time stamp is extended to year/month/day/hour/minute, month/day/hour/minute/second, day/hour/minute/second/10msec. (Ver1.06 or later)
Line status display Records and displays the wave form of 4 signals (chosen from RS(RTS), CS(CTS), ER(DTR), DR(DSR), CD(DCD), CI(RI), EXIN(outside trigger input) along with the transmission / reception data.
Address filter Records only frames of the specified address.
(only when HDLC / SDLC / X.25)
Data display and operations Pause in capture, scroll, paging, jump to the specified screen.
Bit shift display Entire frame can be shifted to the right or left in 1 bit increments.
Protocol translation display SDLC (modulo 8/128), ITU-T X.25 (modulo 8/128), LAPD, PPP, BSC, I2C
Line status LED Two color LEDs of SD, RD, RS(RTS), CS(CTS), ER(DTR), DR(DSR), CD(DCD), CI(RI), ST1(TXC1), ST2(TXC2), RT(RXC).
RS-232C Logic ON (red) , logic OFF (green) , no connection NC (light off)
Other I/F Logic ON (red) , logic OFF or no connection NC (light off)
Interval timer 2kinds; Max. count: 999999 (Resolution: 1ms ,10ms ,100ms)
General-purpose counter 2kinds; Max. count: 999999
Data counter For SD and RD (1 each): Max. count: 4294967295
Trigger function Up to four pairs of trigger conditions and actions can be specified.
Sequential actions, which validate another condition after one condition is satisfied, are possible.
condition Communication error (Parity, MP, framing, BCC, break, abort, short frame can be specified individually.), communication data string up to 8 characters (don't care and bit mask available), idle time more than the specified duration, match time/counter value, logic status of interface signal line and extarnal trigger input
action Stops measurement/test (number of offsets until a stop can be set), validates trigger conditions, controls timer (start/stop/restart), controls counter (count/clear), activates buzzer, saves monitor data on a memory card, sends the specified character string (during manual simulation), and sends pulse output to external trigger terminal OT2.
External trigger output Sends pulse output to external trigger terminal OT1 when all conditions are satisfied. Sends pulse output to external trigger terminal OT2 according to the trigger output specification.
Data search function Retrieves the data with specific condition from capture memory.
condition Communication error (parity, MP, framing, BCC, break, abort, short frame can be specified individually), communication data string up to 8 characters (don't care and bit mask available), idle time more than the specified duration, specified time stamp, and trigger matching data
action Shows the match data at the top or enumeration display (selectable)
Monitor conditions auto setting Measurement conditions such as protocol, transmission speed, (max. 115.2Kbps), data code, synchronous character and BCC check can be set.*5
Auto run/stop function Enables measurement to start and end at the specified time at the selected repeating cycle (monthly, daily, hourly).
Power ON auto run function Enables measurement to start automatically after power is turned ON.
Auto save function Automatically saves the monitored data in the capture memory and saves as communications log file in a SD card or USB flash memory.
Ring save operation is available by selecting APPEND off (re-recording mode) or APPEND on (append mode).
File size BUF (capture memory size) , 1MB , 2MB , 4MB , 8MB , 16MB, 32MB
MAX. files 1024
Delay time function Measures and displays the interval of change in the interface signal line. (current/min/max/average, resolution: 0. 1ms)
Signal voltage measuring function

Measures and displays the value of voltage amplitude:
SD, RD, ER (DTR), and CD (DCD) over RS-232C
SD, RD, RS, and CS over TTL port

 (current value/min/max, ±15-V input range, 0.1-V resolution)
Logic analyzer function Measures the logical change of the interface signal in the sampling clock period, and displays its wave.
Sampling clock 1KHz to 20MHz (14 steps)
Sampling memory Min 2,000
Trigger condition Trigger conditions in the ONLINE monitor functions match. Logical status match between interface signal line and external signal.
Trigger position Before, center, after
Zoom in/out ×8, ×4, ×2, ×1, ×1/2, ×1/4, ×1/8, ×1/16, ×1/32, ×1/64
Other functions Time measurement by cursor, signal line exchange, signal status search
Bit error rate test Conforming to ITU-T G.821 it measures line quality such bit error rate and block error rate*6.
Communication mode Synchronous (SYNC), Asynchronous (ASYNC) Able to have RTS/CTS flow control
Measuring speed 50bps~1. 000Mbps, freely set to four effective digits
Measurement mode Continuous measurememt, specifies the number of receiving bit, specifies the time to measure, repeatedly measurement at the unit of 1 - 1440
Test pattern 26-1, 29-1, 211-1, MARK, SPACE, ALT, DBL-ALT, 3in24, 1in16, 1in8, 1in4
Error bit insertion Inserts 1-bit or 5-bit error in test pattern by key operation.
Measurement range It is able to measure the parameter of the ITU-T advice G.821.
Effective received bit (0-9999999), bit errors (0 to 9999999 to 9. 99E9), bit error rate(0 to 9. 99E-9 to 1), block errors (0 to 9999999 to 9. 99E9), block error rate (0 to 9. 99E-9 to 1), Savail(available measurement time: 0 to 9999999sec), loss count (synch loss: 0 to 9999), error duration (0 to 9999999sec), %EFS (normal operation rate: 0. 000 to 100. 000%)
Simulation function Enables transmission/reception test of any given data in DTE or DCE mode (selectable with pin assingnment).
Transmit data entry Register 160 kinds of transmission data tables (10Groupsx16, total 16K data)
Error data entry A part of transmission data can be registerd as error data such as parity error.
Line control mode Auto (Controls transmission timing with RS(RTS), CS(CTS), ER(DTR), CD(DCD) signal lines automatically in 1 ms increments) or manual (key operation) can be selected.
Transmit driver control Auto control (turning ON driver only during data transmission) or manual mode (linking with ER (DTR) or CD (DCD) key manipulation) can be selected during RS-485 simulation.
MANUAL mode Sends the data assigned to operation keys each time a key is pressed, while checking communications status on the display. Can be used together with the trigger function
FLOW mode Simulates the X-on /X-off control data and flow control procedures of RTS/CTS control line. (Sender and receiver selectable).*7
ECHO mode Returns reception data in frames (buffer echo), in bytes (character echo), or by looping back (loopback echo).
POLLING mode Simulates polling communications procedures. (Sender and receiver selectable)
File management function Measurement data and condition can be saved in a SD card or USB flash. And the format of the data/condition can be used in the PC.
File types Measurement data (.DT), all measurement conditions (.SU), trigger save data (TG SAVEnn.DT), and auto save data (#nnnnnnn.DT)
File controls Normal file display, file display by specified type/created date basis, save, load, delete, delete all, and format
Supported memory card Supported external memory: 2G-16G byte SD card (LINEEYE warrants only the optional SD card.) or a USB flash memory up to 16Gbyte
Printout function Specified range of measurement data can be continuously printed in format corresponding to the display mode. Displayed images can be printed to make hard copies.
LCD Monochrome 240 x 64 dots with backlight
Remote Control PC link software (light edition) is attached*8
AUX(RS-232C) port Mini DIN8 pin connector.
Communication speed: 9600bps to 230.4Kbps (6 steps)
Print out data, Can be used with PC [LE-PC300R], Can be used to upgrade the firmware.
SD card slot Standard size for SD/SDHC memory card. Compatible with the standard of SD association.
USB2.0 device port B-connector in device side. Transfer data in full-speed Can be used with PC [LE-PC300R], Can be used to upgrade the firmware.
USB2.0 host port A-connector in host side. Transfer data in full-speed Can be used to connect with USB flash memory.
Wi-Fi Connection 802.11 b/g/n*9
Frequency range: 2400MHz-2483.5MHz
Transmission power: +20dBm(802.11b), +17dBm(802.11g), +14dBm(802.11n)
Used for PC connection by LE-PC300R
External power supply Nickel metal-hydride battery (Model: P-19S)
Battery operating time*10 About 7 hours
Battery charging time About 2.5 hours
Temperature range In operation : 0 to 40 degree Celsius, In storage : -10 to 50 degree Celsius
Humidity range 85% (RH) max.
Standard CE(Class A)
Dimension, mass 210 ( W ) x 154 ( D ) x 38 ( H ) mm, About 760g
Accessories Monitor cable for DSUB 25-pin (LE-25M1), Monitor cable for DSUB 9-pin (LE-009M2)*11, DSUB25pin-9pin conversion adapter*11, 5 wires TTL prove cable (LE-5LS), AC adapter (6A-181WP09), carrying bag (LEB-01), Utility CD, instruction manual and warranty
*1: To monitor control line, expansion board “OP-SB10N” (which has RS-530 port) is needed.
*2: To use the function, the optional accessories described in the brackets are required.
*3: This mode is used to capture all data in synchronization with clock edges.
*4: Transmission/reception data, idle time, time stamp, and line status items consume 4 bytes of memory at each capture.
*5: This function supports only ASYNC, SYNC/BSC, HDLC/SDLC. Correct auto settings are impossible if the amount of communications data is small or communications data includes a large number of errors
*6: Only ASYNC mode and SYNC mode are available.
*7: Only ASYNC is available.
*8: This is the light edition of optional product “LE-PC300R” (with some limitation for its functions).
*9: Wi-Fi function is available only in Japan, USA, Canada, and EU nations where the product is needed to be compliant with RE directive (2014/53/EU). The Wi-Fi function of this product is set to invalid depending on the country where it is shipped. Please contact LINEEYE for the detail.
*10: The battery operating time was measured under LINEEYE's measurement conditions with the LCD backlight turned OFF.
*11: The options have been substituted by LE-009M2 and DSUB25pin-9pin conversion adapter from LE-009M1 and LE-259AD after the production of Oct. 2019.