●Simultaneous measurement of two Ethernet packet lines and one PoE power
●Output test packets at wire-rate from 2 channels at the same time
●PoE / PoE + / PoE ++ judgment and long-time power recording
●Adds time stamps which can be synchronization by GNSS (PPS) signal
●Automatically records communication logs into large-capacity external storage via USB3.0
●1kg, handheld design. Measurement can be performed by itself without a PC
●Saves data in PcapNG files that can be analyzed by Wireshark
●PC link with LAN, USB, or Wi-Fi (XR only) connection
LE-8500X No Wi-Fi connection
LE-8500XR With Wi-Fi connection
LE-8500X / LE-8500XR is a handy-type communication-protocol-analyzer equipped with a measurement board that can simultaneously measure and test the power supply status of one PoE (Power over Ethernet) and two lines of Ethernet communication data on a line (from 10BASE-T to 1000BASE-T).
It can be widely used for diagnosis and testing of LAN networks and related devices by using the packet monitor function, packet generate (PG) function, statistical analysis function, PoE judgment function, etc. according to the test situation.
The model is equipped with a 7-inch wide-color LCD with a touch panel, thus you can check the measurement data immediately on-site without using a personal computer. You can log the data to a USB flash memory etc. via USB 3.0, thus you can analyze the data in detail after the measurement.
In addition, as the time stamps that are time-corrected with high accuracy by GNSS signals can be added to the monitor data by using an optional GPS antenna, by checking the time stamps you can compare and analyze the data measured simultaneously at two points for a long period of time to investigate a communication failure.
Furthermore, by replacing the standard measurement board with another measurement board (sold as an option), the communication interface to be measured can be expanded later, so they can be widely used from network systems to development testing and maintenance of embedded communication equipment.
Interface | RJ-45 connectors. Port A, B, C, D: 1000BASE-T/100BASE-TX/10BASE-T Port A ? B is failsafe tap※1 |
---|---|
Capture Memory | Capacity: 1Gbyte (96byte to 10560byte for 1 frame) 2 divided use, accidental-erasure protection, and selection of ring buffer and fixed size buffer are available. |
Backup Memory | Measurement conditions and part of the latest data (about 16 Mbytes) can be saved automatically※2 |
Online Monitor Function | Simultaneous recording and real-time display of 2 channels of Ethernet frames flowing between ports A-B and C-D※3 |
Frame Size | 60 byte to 9Kbyte |
Time Stamp | The reception time is added as timestamp data for each received frame. Resolution: 8n seconds / 1u seconds / 10u seconds can be selected Time adjustment by GNSS PPS signal or external PPS signal is available※4 |
Data Display/Control | Scroll display, 2-split comparison display, jump operation to specified screen, mark jump operation |
Translation | Supported protocols: IPv4, ARP, ICMP, TCP, UDP, DHCP, EtherCAT |
PcapNG Conversion | Measurement data can be converted and saved to a PcapNG format file※5 |
Filter Function | Can monitor only the specific frames that match one or two specified conditions. |
Trigger Function | When a specific frame that matches the specified conditions is received or when the external TTL signal changes, it can automatically stop monitoring, count how much the conditions are matched, or output the external TTL signal. |
Filter/Trigger Condition | Layer 2 type (IPv4, ARP, NetBios, IPv6, EtherCAT, type number specified), Layer 2 source address, Layer 2 destination address, IPv4 protocol (ICMP, IGMP, TCP, UDP, protocol number specified), source port number / address, destination port number / address, subnet mask |
Search Function | From the measured data, it can search, cue, and count only the specific frames that match the specified conditions Search conditions: Error frame, specified frame size, measurement port, and specific frame that can be specified in the same way as the trigger condition |
Delay Time Measurement Function | Can measure the time difference between the two specified reception timings among Port A-B Tx, Port A-B Rx, Port C-D Tx, and Port C-D Rx in u seconds, and calculate the current value, maximum value, minimum value, average value, and display them as delay time. |
Statistical Analysis Function | Statistics of two frame counter values can be collected and displayed in a graph at specified intervals (2 seconds to 240 minutes), and all frame counter values can be displayed in real time. Frame counter type: Total number of received frames, number of normal frames, number of broadcasts, number of multicasts, number of pause frames, number of each frame of 0-63 byte length / 64 byte length / 65-127 byte length / 128-255 byte length / 256-511 byte length / 512-1023 byte length / 1024-1518 byte length / 1519 bytes length, number of FCS error frame, number of FCS error frame less than 64 byte length, average data rate for the past 1 second, average data rate for the specified period |
PoE Measurement Function | Measurement, recording, appropriateness judgment, graph display, and dump display for the power consumption, voltage, current, power supply type (Alternative A / B, polarity) of PoE/PoE+/PoE++ (IEEE802.3af/at/bt) between the devices connected to ports A and B. Simultaneous measurement with Ethernet frames is available. Recording interval: 1 msec to 1 sec, maximum number of recordings: 16.77 million times, voltage measurement range: 0 to 60 V (accuracy: ±1% F.S.), current measurement range: 0 to ±900mA (accuracy: ±1% F.S.)※6 |
PG Function | Can output arbitrary packets at the wire rate from ports C and D. Up to 16 types of packets set in the 16 transmission data tables (total 32k data) of each port can be transmitted sequentially from each port for a specified number of times or continuously. Frame gap (interval until the next packet is transmitted) can be set for each transmission data table. |
Ping Function | Can issue a PING command from port C to display the number of responses and response time (current value, maximum value, minimum value, average value). |
Port Blink Function | Blinks the link LED on the port of the hub connected to port C |
Cable Diagnostic Function | Can measure cable length (3 to 100m), disconnection points, short points, and split pair presence※11 Length measurement method: TDR method Length measurement error: ±2m※12 |
Auto Save Function | The contents of the capture memory (monitored data) can be automatically saved as a communication log file in the storage such as the USB memory / SDHC, etc.※7 |
Auto Save Mode | Re-recording mode, append mode, Max stop (records up to specified capacity and stop) mode can be selected |
File Size | Capture memory size, 4M bytes, 16M bytes, 64M bytes, 256M bytes |
Max File Number | 2048 |
Auto Backup Function | Measurement data can be automatically saved at the end of measurement Save destination: Built-in eMMC (latest part of measurement data about 16 Mbytes) or external storage such as USB memory/SDHC card (all measurement data) can be specified |
Time-specified Auto RUN/STOP Function | Measurement operation can be started and stopped at a specified time and at a specified repetition cycle (selectable from monthly, daily, and hourly). |
Power-on Auto RUN Function | Measurement operation can be started automatically after the power is turned on. |
File Management Function | Measurement data and measurement conditions can be saved in an external storage such as USB memory/SDHC in a format that can be read by a PC. |
File Type | Measurement data (.DT), all measurement conditions (.SU), auto save data (#nnnnnnn.DT), screenshot (.PNG), PcapNG format file (.PCAPNG), text conversion (.txt, .csv) |
File Control | Normal file display, file display and sorting by specified type, save, load, delete, delete all files |
Print out*8 | Measurement data can be printed continuously in various formats, and display images can be printed as hard copies. |
Display | 7 inch TFT color LCD with capacitive touch panel |
Line Status LED | 11 LEDs always display the connection status of measurement ports |
LAN Port | RJ45 connector, 1000BASE-T Ethernet: IEEE 802.3 for PC connection |
USB Device Port | Type-C connector, SuperSpeed transfer supported. For PC connection |
USB Host Port | Standard A connector, SuperSpeed transfer supported. For external storage (USB memory/SSD) |
SD Card Slot | For standard size SD / SDHC memory cards, compliant with SD Association standard |
External I/O Terminal | 4-pin connector for TTL level trigger input/output signals |
GPS Antenna Connector | SMA (female) connector for active GPS antenna connection |
PPS Signal Connector | SMA (female) connector for TTL level PPS I/O signals |
Wi-Fi Connection※9 | IEEE802.11b/g/n frequency range: 2412MHz to 2484MHz Transmission power 802.11b: +18.5dBm, 802.11g: +18.0dBm, 802.11n: +17.0dBm |
Power | Attached AC adapter Input: AC100-240V 50/60Hz Output: DC9V 2A |
Battery | Lithium-ion secondary battery (model number: P-26LW2) Battery drive time: 2 hours※10 Charging time: Approximately 3.5 hours when using the AC adapter, approximately 4.5 hours when using the USB Type-C cable (when using a Type-C charger that can supply 2A or more) |
Ambient Temperatures | In operation : 0 to 40 degree Celsius, In storage : -20 to 50 degree Celsius |
Ambient Humidity | 20 to 85%RH (No condensation) |
Standard | CE (Class A) |
Size | 234(W) x 186(D) x 44(H)mm |
Wight | about 990g |
Accessories | LAN cable 2pcs, USB cable (standard A-Type-C), external signal input/output cable (LE-4TG), AC adapter (6A-181WP09), carrying back (LEB-01), utility CD, quick start guide, warranty card |
*1: When the power of this unit is turned off, ports A and B are connected through in this unit, and the link between the devices connected between A and B is maintained. The link may be temporarily disconnected during the startup period and shutdown period of this unit.
*2: Uses a part of eMMC for saving measurement firmware
*3: As data can be recorded to the capture memory at a maximum of approximately 4Gbps, 1000BASE-T high-traffic lines of the two channels can be recorded to the capture memory simultaneously without packet loss, except for some special situations.
*4: A GPS antenna (sold separately) is required for GNSS synchronization. External PPS synchronization requires another unit to which a GPS antenna is connected and an SMA coaxial cable (sold separately).
*5: LINEEYE provides a PC software that can convert the measurement data file of this unit to a PcapNG format file on a PC.
*6: Cannot be used to measure PoE lines in which a current exceeding 720 mA flows continuously for 3 seconds or longer.
*7: Not all frames may be recorded in the storage depending on the high traffic line or the performance of the external storage. The maximum recording speed is about 1Gbps (according to our measurement test using USB3.0 connected SSD)
*8: A dedicated printer (SM4-31W) is required.
*9: LE-8500XR only. For PC connection. The "Wi-Fi module" used for the product conforms to SRRC(China), FCC (USA), CE (EU), TELEC (Japan), KCC (Korea), ISED (Canada), NCC (Republic of China), however, as the "product" the Wi-Fi function is available only in Japan, USA, Canada, and EU nations in compliance with RE directive (2014/53/EU).
*10: According to our test conditions assuming a normal usage situation
*11: Due to the open measurement method, cable maps (connection information) cannot be displayed.
*12: Does not include uncertainty of NVP value. The NVP value must be set appropriately depending on the cable.