Analog Pod
OP-8AT
Overview
CAN/high-speed analog measurement expansion set A pod that can be used by attaching to the SB-C2AN to perform high-precision analog measurement and temperature measurement using thermocouples.
* This pod is different from the analog pod (OP-8AH) included with SB-C2AN.
■Specifications
Model | OP-8AT |
---|---|
Applicable product | SB-C2AN |
Channel | Number of channels: 8, 24-bit resolution, built-in high-precision ADC, screwless terminal block |
Input impedance voltage resistance |
1MΩ, withstand voltage: max±50Vpk, channel-to-channel isolation 350V (AC peak/DC) |
Signal isolation voltage | Between analog input and analyzer 1500V (AC peak/DC) 350V (AC peak/DC) between each channel of analog input |
Input range*1 | ±30V, ±10V, ±1V, ±100mV, 0-20mA, temperature K, J, T, E, N, R, S, B type thermocouple compatible |
Measurement accuracy※2 | ±30V range ±(0.05% rdg + 3mV), ±10V range ±(0.05% rdg + 2mV), ±1V range ±(0.05% rdg + 0.2mV),
±100mV range ±(0.05% rdg + 50µV), 0-20mA current range ±0.05% FS, Temperature range: See below table |
*1: For the 0-20mA range, an external current detection resistor (250Ω or 50Ω, accuracy±0.1% or less) is required on the input terminal block. is.
*2: rdg represents the accuracy for the reading value, and FS represents the accuracy for the full scale of the range. Current accuracy does not include external resistance errors.
Compatible thermocouple | K, J, T, E, N, R, S, B type | |
---|---|---|
Measurement temperature range |
K type: -200℃ ~ 1370℃ J type: -210℃ ~ 1200℃ T type: -200℃ ~ 400℃ E type: -200℃ ~ 1000℃ N type: -200℃ ~ 1300℃ R type: 0℃ ~ 1760℃ S type: 0℃ ~ 1760℃ B type: 400℃ ~ 1800℃ |
|
Cold junction compensation | Internal compensation, external compensation switchable | |
Disconnection detection function | On/off switchable (applied current: approx. 180nA) | |
Measurement accuracy*1 | K type |
-50℃ ~ 1370℃ : ±(0.05% rdg + 1.0℃) -200℃ ~ -50℃ : ±(0.05% rdg + 2.0℃) |
J type |
-50℃ ~ 1200℃ : ±(0.05% rdg + 0.8℃) -210℃ ~ -50℃ : ±(0.05% rdg + 1.6℃) |
|
T type |
-50℃ ~ 400℃ : ±(0.05% rdg + 1.0℃) -200℃ ~ -50℃ : ±(0.05% rdg + 2.0℃) |
|
E type |
-50℃ ~ 1000℃ : ±(0.05% rdg + 0.6℃) -200℃ ~ -50℃ : ±(0.05% rdg + 1.2℃) |
|
N type |
-50℃ ~ 1300℃ : ±(0.05% rdg + 1.5℃) -200℃ ~ -50℃ : ±(0.05% rdg + 3.0℃) |
|
R type S type |
400℃ ~ 1760℃ : ±(0.05% rdg + 3.5℃) 0℃~400℃: ±(0.05% rdg + 6.0℃) |
|
B type |
800℃ ~ 1800℃ : ±(0.05% rdg + 4.0℃) 400℃ ~ 800℃ : ±(0.05% rdg + 7.5℃) |
|
Cold junction compensation accuracy*2 | ±1.0℃ |
*1: Accuracy at ambient temperature of 18 to 28°C and after 20 minutes after power on, does not include thermocouple error.
If the above ambient temperature range is exceeded, add 1/20 of each error value for every 1°C.
If the above ambient temperature range is exceeded, add 1/20 of each error value for every 1°C.
*2: In environments where a part of the measurement pod is locally heated or cooled, cold junction compensation accuracy cannot be guaranteed.