******************************************************************************************* Firmware Transfer Program <> Version 1.13 ******************************************************************************************* Thank you for your purchase of a LINEEYE portable communication analyzer. This document includes how to update firmware of the analyzer. To use correctly, you are advised to read and understand this thoroughly. =========================================================================================== 1. Appropriate models This program can be used with the following: LE-7200 / LE-3200 / LE-2200 / LE-1200 / LE-7000 (hereinafter "communication analyzer") =========================================================================================== 2. Warning (1) Do not turn off the power supply of your analyzer during this program running. If the power supply is turned off during writing on ROM, your analyzer may not operate at all. (2) Be sure to use the AC adapter when you update firmware using this program. The power source may be turned off due to the consumption of the battery without using the AC adapter when updating. (3) Transmission speed must be 115.2kbps. Use the serial port which supports 115.2kbps. (4) The firmware file is different depending on models. Do not update using the wrong firmware file. =========================================================================================== 3. Explanation of command (1) Command : le7firm (2) Function : transfers firmware to your analyzer, and writes on ROM. (3) Format : le7firm_-p_-f_ COM port name : Specifies the port name connecting to your analyzer such as COM1 and COM2. -f : Switches the message display. Set [-f] normally. File name : Specifies the firmware file name to be transferred. The firmware file is different depending on models. _ : Enters space. (4) Commentary : - Transfers firmware to your analyzer, and then writes on ROM. - When the processing status does not appear, it shows that the program is not operating normally. In this case, press the the Ctrl+C keys at once to force the program to stop. On the other hand, if you press the Ctrl+C keys while the program is running normally, your analyzer may not operate correctly afterwards. =========================================================================================== 4. Preparation (1) Make sure that you have the firmware file and this program in the same folder. If not, copy them in the same folder. The firmware file corresponding to each kind of the models is as follows. Make sure if the firmware file matches the model of your analyzer. Model File Name LE-7200 : LE7200.FW LE-3200 : LE3200.FW LE-2200 : LE2200.FW LE-1200 : LE1200.FW LE-7000 : LE7000.FW (2) Connect the AUX port of your analyzer to the serial port of a PC with the included AUX cable. Depending on the connector shape of a PC, the conversion connector for 9 Pin-25 Pin may be required. (3) Power on holding down the "SHIFT" and "LOAD/SAVE" key of your analyzer. When "Firmware Loader" appears, it means the preparation has completed. If it does not appear, repeat the same operation mentioned above till the preparation completes. =========================================================================================== 5. Starting Operation (1) Execute Command prompt (or MS-DOS prompt) from the start menu of Windows. (2) Change the current directory to the directory holding this program. (3) Enter the command following the command format. Example : To update firmware for LE-7200 which connects to the COM1 port le7firm_-pcom1_-f_LE7200.FW ("_" indicates space.) (4) Press the "ENTER" key of a PC. It starts transferring the firmware file to your analyzer. Then, the processing status will appear on the screen of the PC. (5) When transferring is completed, the following check will be executed in your analyzer in order: erasing ROM, its check, writing and its check. Load....OK. Erase....OK. Erase Check....OK. Program....OK. Verify....OK. Complete. The program will be ended. Reset processing will be automatically executed at your analyzer side, and the opening screen will appear. The firmware update has completed. ######################################################################### ## Caution ## ## Never turn off the power supply of your analyzer until operation ## ## of both (4) and (5) will be finished. Otherwise, transfer of the ## ## program may not be completed correctly. To make matters worse, ## ## the program being written till now may break. Erasing or writing ## ## of the ROM may take nearly three minutes. ## ######################################################################### (6) The message "Replace Boot Block?" may appear after transfer operation of (5). Select "YES" normally. Enter [1] and press the "ENTER" key from the keyboard of PC. If you execute the firmware transfer program by mistake, select "NO." Enter [2] and press the "ENTER" key from the keyboard of PC. The program finishes without writing on ROM. (7) When transferring firmware and writing on ROM finishes, the opening screen will appear on the screen of your analyzer. If you still see the firmware loader screen on the screen, run the program again. In this case ######################################################################## ## Do not turn off the power supply of your analyzer to run the ## ## program. ## ######################################################################## If nothing changes after reexecting, there may be the possibility that the is broken or the software is erased by accident. In such a case, Please contact the LINEEYE distributors or LINEEYE CO., LTD. =========================================================================================== LINEEYE CO., LTD. *URL http://www.lineeye.com *E-mail info@lineeye.com *******************************************************************************************