Firmware Version History for LE-7200/LE-3200/LE-2200/LE-1200
Version.
1.12 Jul. 30, 2010
- Add the function in the BERT which external trigger output will be LOW when detecting the error bit.
After the test (finish the each time of REPEAT mode), it will become HIGH automatically.
- Able to use the 2G byte CF card for LE-1200.
[ detail ]
Version.
1.11 Sep. 17, 2009
Specification change
- Add a display mode for ASYNC frame per a time stamp
- Add the display of difference between two time stamps.
(Press [SHIFT] + [TIME/COUNT]. Cannot be used while measuring.)
- Change the default of “FRME TIME” to 5ms (It was 100ms) at the Configuration menu.
(It will be recognized as a frame end if there are no communications for more than 5ms in the case of ASYNC.)
- Correct miner bug of Bit Shift Display on BURST data.
- Correct miner bug of changing display code when turning of the power.
[ detail ]
Version.
1.10 Oct. 27, 2008
Specification change
- Accepts the bigger size of CF card. (only for LE-3200/2200/1200.LE-7200 supports 8Gbyte as same as before.)
Model |
New Firmware(V1.10) |
Before(1.09) |
LE-1200 |
1G Byte |
512M Byte |
LE-2200 |
2G Byte |
1G Byte |
LE-3200 |
2G Byte |
1G Byte |
- Supports the active type of Simulation of OP-1C (adapter for current loop).
- Adjusts the timing of start/stop conditions of I2C.
- Corrects the miner bug of MBA process for file management.
- Corrects the problem that stopping the process when pressing the incorrect key for auto configuration.
[ detail ]
Version.
1.09 Jun. 21, 2007
Specification change
- Revised the time display between cursors in the Logic Analyzer function.
Corrected the counting number to be 1ms after it counts 999us.
(It used to be 10ms instead of 1ms)
- Corrected the timing signal in the LCD display.
[ detail ]
Version.
1.08 Mar. 31, 2006
Specification change
- Added REPEAT (repetitively measuring) mode to the test mode of BERT.
- Added Print out/TEXT output function of BERT measurement result at the time of REPEAT mode of BERT.
- The frame end detection time of ASYNC and Burst can be set within the range of 1 to 100 ms.
- Accelerated the time when turning RS-422/485 driver OFF after data transmission on driver control AUTO of simulation function.
- The measurement information other than the monitor data can be transmitted and received remotely when measuring (in RUN).
[ detail ]
Version.
1.07 Nov. 30, 2005
Specification change
Optimized the software process related with power consumption.
Bug Fixes
Target Model : LE-7200-E, LE-3200-E, LE-2200-E
- Added the process not to do synchronism reset when monitoring the data of the transparent mode of SYNC-BSC.
- Fixed a minor bug of the station address setting process at the polling simulation.
- When performing reappearance transmission of the data in the buffer whose final data is the frame terminal data other than time information at the buffer simulation, a bug to which inaccurate data is outputted was fixed.
Version.
1.06 Jun. 30, 2005
Specification change
The specification had
been changed so that the remote operation from PC
link software cannot change AUX communication condition
of analyzer.
Bug Fixes
- Corrected the problem that ","
which should be inputted by "D" key cannot
be inputted on the editing operation of the transmission
data table when the data code setting is ASCII.
- Corrected the problem that the red light LED
of the clock signal ST1, ST2 and RT is not lighted,
and the same clock signal cannot perform logic analyzer.
(This problem happens only on the firmware V1.05
of LE-7200, LE-3200 and LE-2200)
Version.
1.05 May 19, 2005
Bug Fixes
Correct the problem with margin for
the decode circuit of IrDA.
Version.
1.04 Apr. 27, 2005
Supported
larger-capacity memory cards.
Firmware |
Ver.1.04 |
Ver.1.03 |
LE-7200 |
6G bytes |
4G bytes |
LE-3200, LE-2200 |
1G bytes |
512M bytes |
Bug Fixes
- Corrected the problem that an external
trigger setting (RISING and FALLING) operated reversely
with actual input logic.
- Corrected the following problem: when the total
data of transmission data table shows the odd number,
saving the setting file with simulation programs
into a memory card causes to stop operating with
the exception screen appear.
- Corrected the following problem: by using the
auto save and auto run functions together, when
the auto run is in the ON setting, the exception
screen stops operating after the auto stop stops
operating.
Version.
1.03 May 11, 2004
Expands
the AUTO RUN function
- Added the function to repeatedly start
and stop measurement at the appointed time (monthly,
daily, hourly).
- Added the function to automatically start measurement
after powering on analyzers.
Expands the AUTO SAVE function
- Added the function to append data to a file.
- Improved safety and high-speed access by changing
file access system
Previous specifications: |
Damages the file when power is down during
running. |
Current specifications: |
Damages the file when power is down during
running and accessing to CF or HDD cards. |
* When power is down during accessing to CF or HDD cards, it may damage them.
Therefore, do not let power down when using this function. |
Filter function
Added the filter function to the file
table which lets you check information by kinds
of data, file, time, and stamp.
*
Users of the PC Link software LE-PC300 are required
to update to version 1.00.03.
Bug Fixes
Corrected errors that had caused to
display incorrectly after the search was completed.
Version.
1.02 Jun. 15, 2003
Bug Fixes
- Corrected the problem with printing
without the BCC OK data at the time of printing
the screen for the normal data and line status.
- Corrected the problem that the wrong
name of a signal line was shown when V.35 data was
displayed on the wave monitor screen.
** The associated data file conversion program has
been also updated.
Version.
1.01 Jun. 3, 2003
Bug Fixes