Update
LE-PC87 Version History
Version 1.07 Jan. 21, 2019
- OBD2 option is added to the text conversion function.
- Added the block size at remote monitor mode up to 128MB and extended the continuous recording capacity up to max.256GB.
- Supported the Auto Save capacity of 2048 files (max.) which has been supported by V1.16 of OP-SB87
- Fixed the bug with which the analyzer sometimes cannot judge correctry the status of RUN start/stop when inserting a CD card.
[ detail ]
Version 1.06 Jul. 22, 2015
- Supports Pass-filter and Cut-filter of CAN added on OP-SB87 Ver.1.15.
- Adds Auto-power off setting while measuring in Auto-Run added on OP-SB87 Ver1.13.
- Adds Inter-Lock setting which prohibits outputting data added on OP-SB87 Ver1.12.
[ detail ]
Version 1.04 Sep. 20, 2013
[Improvement / Addition]
- Able to display all frames including remotes and errors that match with IDs on the Watch Data display.
- Support sub-data tables for CAN simulation.
- Display property of measured data.
[Improvement / Addition]
- Correct the bug of time stamp when the units of 1us/10us/100us reach to the maximum number.
[ detail ]
Version 1.03 Apr. 5, 2012
[Improvement / Addition]
- Add the Analog Measurement mode in the Monitor function.
Add the configuration for Analog Measurement mode, data display, and waveform display function for PC link software. - Support baud rate of LIN up to 26Kbps.
- Add "HMS"(Hour/Minute/Second) in the time stamp resolution.
- Add "Stop" in the "BT RUN lock" in the system configuration.
- Add the timer counter display.
- Add "Full stop" and "Append" mode to save the remoter monitor data.
- Display "Tq" when setting the baud rate in CAN configuration.
- Improve the configuration of frame end time in LIN configuration.
- Add the CAN error frame search function. (only supported by PC link software)
[Improvement / Addition]
- Correct the TRG OUT setting in trigger action.
[ detail ]
Version 1.02 Oct. 20, 2011
[Bug Correction]- Correct the bug that LE-PC87 abends operation after CSV conversion of data with usec time stamp without showing data on the screen. Also after CSV conversion of LIN ID data with framing errors.
- Correct the bug that LE-PC87 cannot have CSV conversion properly, if data showing on the screen and target files of CSV conversion have different resolution of time stamp.
- Correct the bug that title of configuration is wrong after TEXT conversion.
[ detail ]
Version 1.01 Oct. 6, 2011
[Improvement / Addition]- Add the “On-Line Help” function both in Japanse and English.
- Able to type the COM port number when connecting to the serial port
- Able to open the measured files in order even thought the files were moved from original place.
- Add to search the CAN CRC error and data frame without data length.
- Add the CAN form error [F], and it can be converted into text/CSV format. *1
- Add “10ns” at sampling clock in the waveform monitor setting. *1
- Correct the bug that CAN ACK error [A] is displayed as [E] (error) after CSV conversion.
- Correct the bug that CAN CRC error [C] is displayed as [E] (error).
- Correct the bug that “Connecting” is displayed in the status bar even thought there is a connection error.
- Correct the bug that “Open files” cannot be operated when there is a connection error.
- Correct the bug that “Ch1 & Ch2” is always selected at error search.
- Correct the bug that “Setting synchronization” is not able to change.
- Correct the bug that LE-PC87 setting will be erased (becomes default setting) when connecting to the analyzer.
- Correct other miner bugs.
*1 Neet to use with OP-SB87 firmware version 1.05 (It will be released in the end of October 2011.)
[ detail ]
Version. 1.00 Mar. 30, 2010
LE-PC87 released.