Version. 2.10 Aug 19, 2020
  • Fixed a bug that using OP-SB85L the logic analyzer display of TTL measurement was sometimes disordered when sampling at 100MHz.
  • Fixed a minor bug in the automatic backup process to SRAM.
  • Fixed a bug that overrun mark is not written.
Version. 2.09 Jul 5, 2017
  • Supports 128Gbyte CF card.
  • File number limitation for th auto save function has extended up to 2048.
Version. 2.08 Feb. 20, 2015
  • Corrects the minor bug on waveform editor in PULSGEN mode.(LE-8200A only)
  • Adds the remote transmission/reception handling for edited data in PULSGEN mode.(LE-8200A only)
  • Adds the remote transmission/reception handling in the expanded simulation tables.
* To add the remote handling, LE-PC800G (Ver1.08) is needed.
Version. 2.07 Jan 20, 2015
  • Increases the number of pre-resistered data tables up to 160.(before 16 tables)
  • Able to output the pulse signal into external signal "TRGOUT" when satisfying triggers.
  • Adds auto-power off function while in the waiting mode of Auto-run function.
  • Adds the conditions of time stamp setting in the tile of print out data.
  • Improves pasing operation of configuration setting
  • Improves the timing of driver auto-control of RS-530(RS-485)
  • Corrects the bug when loading data file with Analog Wave Monitor data.
  • Corrects the bug that frame which contains 128byte or more cannot be printed correctly in the frame dump format.
  • Corrects some minor bugs of display message.
Version. 2.06 Jun 18, 2014
  • Supports the pulse generation mode of LE-8200A.
  • Adds the function of prohibiting simulation and BERT functions.
  • Correct the bug on buffer protection for loading data file.
  • Correct a minor bug on backward key operation.
  • Correct the typographic error on error massages.
Version. 2.05 Mar 18, 2014
  • Add an icon for CF card on the list of files.
  • Add a function of renaming on the list of files, excepting the extension part. (Shift+F3)
  • Change the company name from "LINEEYE co., ltd." to "LINEEYE CO., LTD" in the opening screen.
  • Change the display of accessing to the CF card on the top right of the screen.
  • Correct the bug that Page size is initialized after rebooting.
Version. 2.04 Jan 22, 2013
  • Add information of analyzer in the measured data.

  • Add information of analyzer and date of measuring in front of text conversion data or print-out data.

  • Improve ABORT operation not to record frames of less than 2bytes.

  • Correct a bug that unnecessary data after end-frag is added in the next frame when setting NRZI: AR.

  • Add STOP (stop measuring when low battery) setting in the “BT RUN lock” in the “SYSTEM” menu.

  • Improve access timing to the CF card.

  • Correct a bug that “RT” is displayed as “7” when “P-type” is “DIAG” in the X.25 packet translation display.

  • Correct a minor bug in the Guide message in the configuration screen.

[ detail ]

Version. 2.03 Nov 1, 2011
  • Add Logic Analyzer (Wave monitor) function at max 100MHz sampling speed.
  • Support Bit sequence at LSB First (SPI protocol) when using TTL/I2C/SPI expansion board (OP-SB85L/OP-SB85L).
  • Able to transmit data when Clock phase is “0” without SS signal at SPI simulation.
  • Set back the SDO signal to be “1” when there is a rising edge of SS signal or another clock after transmission of the last bit at SPI Slave simulation.

[ detail ]

Version. 2.02 Oct 12, 2010
  • Correct bug of wrong position of active status for external trigger signal when using standard board.
  • Correct bug that analyzer cannot measure HDLC communications when starting flag is also used as ending flag.
  • Correct bug that HDLC short frame is recognized as normal frame.
  • Correct bug of invalid trigger function when starting flag is set as trigger condition.
  • Correct bug of capturing loss when there is difference on speed between transmission and reception.
    LINEEYE warrants that analyzer can measure communications if the difference on speed is within 40%.

[ detail ]

Version. 2.01 Sep 14, 2010
  • Correct the bug of mis-counting the date of timestamp when measuring data for a couple months.
    (Timestamp will be incorrect when measuring into another month.) Timestamp will be correct when turning off the analyzer.
  • Correct the bug of auto-saving. When there is not enough capacity in the CF card, there will be some corrupt auto-saving files and become error. It will not happen when specifying the size and numbers of auto-saving file within the capacity of the CF card.
  • Correct the guide message in English, "1:Stop" is changed to "1:Count" at "Action" of the Data Retrieval function.

[ detail ]

Version. 2.00 May 18, 2010
  • Support TTL signal level of HDLC/SPI communications (when using with OP-SB85/OP-SB85L)
  • Improve the capability of measuring SPI communications.
  • Improve the ways of accessing to the CF card file.
  • Correct the miner bug of remote control.

[ detail ]

Version. 1.00 May 20, 2008
  • First official version