PRODUCT
TTL monitor prove pod
(for LE-200PR/LE-150PR)

OP-5ML

Specification
TTL monitor prove pod OP-5ML
Applicable Analyzers LE-200PR / LE-150PR / LE-200PS / LE-150PS / LE-150P / LE-150L
Input Signal SD、RD、RTS、CTS、DSR、DTR、DCD、CI
Input Level Threshold Value Signal Level High Low
5.0V Min. 3.5V Max. 1.5V
3.3V Min. 2.2V Max. 0.9V
1.8V Min. 1.3V Max. 0.6V
Signal level is adjustable by DIP switch.
Input Hysteresis Voltage Min. 0.3V to Max. 1.2V
Input Impedance 100KΩ(0V≦,Vin≦,+5V)
10KΩ(Vin<0V, +5V<Vin)
Input Capacity Less than 10pF
Maximum of Input Voltage ±25V
Output Pull-up Voltage for Testing Possible to output test voltage corresponding to DIP switches of No.2-No.4 through resistance of 1.5KΩ. (Possible to use for pull-up of target signal of testing at open collector output.)
Dip Switch Signal polarity and input level are selectable.
No. Switch Meaning
1 Signal Polarity
2 5.0V signal level
3 3.3V signal level
4 1.8V signal level
Power Supplied from the analyzer
Weight&Size of Pod 78(W) x 92(D) x22(H), 240g
Prove Unit Length of Probe lead: 170mm
Test Clip: 10 Croc clip: 1
Length of Probe Cable 300mm