PRODUCT
CAN FD/CAN/CXPI Expansion Kit
(For LE-8200A/8200)
(For LE-8200A/8200)
OP-SB87FD
Specification
Applicable Analyzer | LE-8200A/LE-8200 |
---|---|
Interface | CAN/CAN FD: ISO11898/ISO11898-1:2015 (Dsub 9-pin male connector x2, inch screw #4-40) CXPI: JASO D 015-3:2015 (two header3 pin connectors) |
Traceiver | CAN/CAN FD: MCP2542FD (Microchip) or equivalent CXPI: BD41000AFJ (Rohm) or equivalent |
Channel | 2 channels in the combination of CAN, CAN FD, and CXPI |
Extended Protocol | CAN-FD(ISO/Non-ISO), CAN2.0B, DeviceNet*1, CXPI |
Communication Speed | CAN: Up to 1Mbps CAN-FD: Up to 1Mbps, when BRS recessive 1M, 2M, 4M, 5Mbps CXPI: 5kbps to 20kbps |
Monitor function | CAN/CAN FD: Standard and extended format are supported. Sample point can be set.*2 CXPI: Normal frame and burst frame are supported. Arbitrary speed can be set. |
ID Filter | Only the specified acceptance ID (bitmask can be specified) can be recorded for each channel. You can specify 8 path IDs and 8 cut IDs and filter by AND condition with acceptance ID.*3 |
Time stamp | 9-digit display. Real-time/difference-time display. Resolution: hour/minute/second, minute/second/1ms, 100µs, 10µs, 1µs can be specified. |
Trigger function | OR operation and sequence operation are available by specifying up to 8 conditions and actions. |
Trigger Condition | Error (non-ACK, ERROR frame, Parity, Framing, CRC)*4, specified data frame (channel, ID, data, data offset, data bitmask), specified remote frame (channel, ID), timer match, counter match, external signal logic, external trigger input |
Trigger Action | Stop measurement, save memory card, timer control, counter control, specified data transmission, buzzer, enable/disable trigger condition, external trigger output |
Simulation function | Pre-registered test frame (CAN/CAN FD: 16 types, CXPI: 16 types) transmission test is available. It can automatically increase/decrease (sweep)*5 the data of the specified position in the data field. |
CAN/CAN FD test | Multiple frames selected by key operation can be transmitted at each specified cycle (number of transmissions can also be specified) |
CXPI test | Master mode/slave mode, event trigger method/polling method can be specified. ID can be sent by schedule transmission. Sends ID match response. |
External signal input | Real-time display of the external signal status of 4 channels by the LED Signal logic and voltage value can be recorded in conjunction with data Signal voltage value can be continuously measured at a specified cycle (measurement range: ±15V, measurement accuracy: ±1%FS) |
Accessories | The expansion board, line state sheet, two Dsub9 pin monitor cables, two 3-wire probe cables, external I/O cable, manual, warranty card |
*1: Only raw data can be displayed.
*2: The sampling points which can be set are limited depending on the communication speed.
*3: Available only for CAN/CAN FD.
*4: Non-ACK and ERROR frames are valid only for CAN/CAN FD.
*5: Endian, initial value, three-step target value, and the time to target can be specified.