Specifications
Interface (standard) | RS-232C (V.24), RS-422/485 (RS-530) | ||||||||||||||||||||||
Interface (optional) | current loop, 3V/5V TTL (I2C not available) | ||||||||||||||||||||||
Protocol |
|
||||||||||||||||||||||
Capture memory |
|
||||||||||||||||||||||
Baud speed | Full duplex: Max. 250 Kbps Half duplex: Max. 250 Kbps |
||||||||||||||||||||||
Internal clock (bps) | Enables to set user-defined speed
for transmission/reception at the range from 50 to 250
Kbps in 4-digit decimal figures. Setting error : +0.01% and -0.01% or less |
||||||||||||||||||||||
Data format | NRZ | ||||||||||||||||||||||
Data code | ASCII, EBCDIC, JIS7, JIS8, Baudot, Transcode, IPARS, EBCD, EBCDIK, HEX | ||||||||||||||||||||||
Character framing | ASYNC: Data bit (5/6/7/8) + parity bit (0/1) + stop bit (1/2) | ||||||||||||||||||||||
Parity bit | NONE, ODD, EVEN, MARK, SPACE | ||||||||||||||||||||||
Multiple-processor bit | Displays 1/0 state of multiple-processor bit with a special mark | ||||||||||||||||||||||
Bit transmission order | LSB first, MSB first (switchable) | ||||||||||||||||||||||
Polarity inversion | NORMAL, INVERT (switchable) | ||||||||||||||||||||||
Error check | Parity (ODD, EVEN, MARK, SPACE), framing, break, BCC (LRC, CRC-6, CRC-12, CRC-16, , CRC-ITU-T, FCS-16, FCS-32) | ||||||||||||||||||||||
Monitor function | Handles half-duplex and full-duplex
communications.
|
||||||||||||||||||||||
Protocol translation display | PPP, BSC | ||||||||||||||||||||||
Interface lead
status LEDs (2-color LEDs) |
SD, RD, RS (RTS), CS (CTS), ER
(DTR), DR (DSR), CD (DCD), CI RS-232C - Indicates the logic of signals with 3 modes: ON (red), OFF (green), NC (not lighting). Others I/F - Indicates the logic of signals with 2 modes: ON (red), NC (not lighting). |
||||||||||||||||||||||
Timer/counter | Interval timer: 2kinds (Max. 999999,
resolution: 100ms, 10ms, 1ms selectable), Universal counter : 2kinds (Max. 999999) Data counter: 1 each for SD and RD (Max. 4294967295) |
||||||||||||||||||||||
Trigger function |
|
||||||||||||||||||||||
Data search function | Shows the match data at the top or
enumeration display (selectable).
|
||||||||||||||||||||||
Monitor condition auto setting | Protocol, transmission speed (Max. 115.2Kbps), data code, character synchronous, enables to auto-set the measurement conditions such as BCC | ||||||||||||||||||||||
Auto run/stop function | Enables measurement to start and end at the specified time at the selected repeating cycle (monthly, daily, hourly). | ||||||||||||||||||||||
Power ON auto run function | Enables measurement to start automatically after power is turned ON. | ||||||||||||||||||||||
Auto save function | Enable to auto-save data in the
capture memory, which is being monitored, as log file
onto a memory card. File size: BUF (capture memory size), 1M, 2M, 4M, 8M MAX. files: 512 |
||||||||||||||||||||||
Delay time measurement | Measures and displays the time between changes of interface signal lines (resolution 0.1ms) | ||||||||||||||||||||||
Logic analyzer | Sampling clock : 1KHZ to 20MHz (14
steps) Sampling memory : min. 2000 sampling Trigger: matching the signal line and logic state of the external signal Trigger position : before, center, after Scale-up/down : *16, *8, *4, *2, *1, *1/2, *1/4, *1/8, *1/16, *1/32, *1/64 Time measurement by the cursor, exchange the signal lines, search a signal state |
||||||||||||||||||||||
Bit error rate test | Measures error rate conforming to
ITU-T Notification G.821 by loop-back test or
interactive test. Measurable in the ASYNC mode DTE/DCE pin assignments selectable Max. speed: 250 Kbps Pattern : 26-1, 29-1, 211-1, MARK, SPACE, ALT, DBL-ALT, 1in4, 1in8, 1in16, 3in2 (Inserts 1-bit or 5-bit error in test pattern by key operation.)
|
||||||||||||||||||||||
Simulation function | Enables the transmission test of user-defined data
(DTE/DCE pin assignments selectable) Transmission data memory: 16k Enables to divide to 16 kinds of the data tables for registration. Enables to register parts of transmission data as error data such as parity error. Enables to preset the interface signal line's change and transmission timing Enables to control the transmission driver for RS-485 |
||||||||||||||||||||||
MANUAL mode | While checking communications condition on the monitor, specified data can be transmitted as pressing the corresponding keys with the transmission trigger function when the trigger conditions are matched. | ||||||||||||||||||||||
FLOW mode | Simulates on the transmission and reception-lines using X-on/off flow control or the control line handshake of RTS/CTS. | ||||||||||||||||||||||
ECHO mode | Returns reception data by a frame unit after specified response time. | ||||||||||||||||||||||
Display | Monochrome LCD, 240 x 64 dot, without backlight | ||||||||||||||||||||||
Memory card interface | Supports the dedicated memory cards
for 16MB, 64MB, 512MB (Flash card) Saves/loads the measurement conditions, capture data, simulation data |
||||||||||||||||||||||
AUX (RS-232C) port | RS-232C, 9600 to 230.4Kbps (6
steps) Data output, remote controls input/output from the external devices, input for updating to firmware, PC link software (LE-PC300F) |
||||||||||||||||||||||
Printer interface | Centronics 14 pin: LCD display screen, printing continuous format of measurement data | ||||||||||||||||||||||
Power supply | Built-in NiMH battery, AC adapter, DC9V, 1.7A (AC100 to 240V, 50/60Hz) | ||||||||||||||||||||||
Battery operating / charging time | Operating time: approx. 8hours charging time: approx. 2.5hous |
||||||||||||||||||||||
Dimensions |
|
||||||||||||||||||||||
Environmental requirement | Temperature range: 0 to 40 degree Celsius
centigrade (operating) ; -20 to 60 degree Celsius
(storage) Humidity : 90%RH or below (no condensation) |
||||||||||||||||||||||
Accessories |
|
||||||||||||||||||||||
Option |
|