This model is discontinued. The successor is LE-2500XR.
Synchronous and asynchronous are possible to be
monitored up to 115.2kbps. LE-2100 is those kinds of a
high-performance analyzer which is capable of monitoring,
simulation and BERT.Supports PPP (point - to - point protocol), translation of HDLC and X.25.
Not only RS-232C of a standard interface but also expandability supports RS-422/485, X.21, V.35, current loop, TTL and IrDA with option adapter.
See options | LE-PC100 | LE-PC200-E | Adapter | ||||||
See details on product | Specifications |
Monitoring
Supports Max. 115.2 kbps of Communication
Asynchronous and synchronous communications are possible up to a max. 115.2 kbps. Separate speeds can be set for transmission and reception.Multiple Protocol Support
LE-2100 supports the following protocols; ASYNC, SYNC, BSC, SDLC(NRZ/NRZI), HDLC(NRZ/NRZI), PPP and packet communications(ITU-T X.25).Also, X.25 level 2(frame level), level 3(packet level), SDLC translation display and BSC translation display are supported. One-touch switching makes analysis or observation speed up.
Analysis of Interface Signal Line
2-color LEDs indicate (red- green- out) signal high/low level and disconnection, making it easy to confirm cables are connected.Also, using a delay time feature, the change of individual signal lines can be measured in 0.1ms resolutions.
Time Stamp and Idle Time Measurement
The data and time of transmission/ reception are recorded on data frames. Then, using an auto run-stop feature with which the user specifies measurement start and end times, measurements can be performed unmanned and the time of errors easily and comfortably checked later. LE-2100 can also measure the amount of idle time between communications frames and closely monitor transmission/reception response and communications timeout status.Large Memory Buffer
Incorporates a large memory buffer for long-term measurement. In the buffer mode, a loaded card acts as expanded memory space, boosting storage area to maximum 1.2MB. 2-dividing ring buffer for comparing data and protection to safeguard data against misoperation or mishandling.Trigger Feature
First of all, two actions will be set up to four pairs. One of them is the action of trigger conditions. The other is it of when the conditions are satisfied. And then, the followings will be able to performed under the conditions of specific data string receipt (Max. eight characters), error occurrences, interface signal line changes and etc; automatic stop of monitoring, timer/counter control and etc.Moreover, the timer/counter function with the trigger function allows you to be able to measure specific data, the number of error occurrence, and response time from transmission and reception sequence. As a result of that, the clarification of intermittent troubles will be performed effectively.
Auto-Configuration
Data on the communications line can be analyzed. And settings such as baud rate and data framing automatically set based on findings. This is effective for monitoring lines of unknown communications conditions.Simulations
Five Kinds of Simulation Functions
[ MANUAL mode ] |
The MANUAL mode allows you to send the data registered in transmission table which corresponds to the "0" to "F" keys. The data can be sent with the press of a key. While checking replies from a unit under development with the monitoring feature of LE-2100, you can easily and simply test the communications process. You can also send fixed data by registering it under a key combination of the SHIFT and "0" to "D" keys, as well as turn RS and ER signal lines on/off with the SHIFT and "E"/"F" key combinations. |
[ MATCH mode ] |
In the MACH mode, when "SEND" is selected as the trigger action and that condition is satisfied, registered data can be sent after a set amount of reply time elapses. By triggering a reply transmission with a specific type of data or error as the trigger condition, timeout processing and error response operations can be easily checked. |
[ FLOW mode ] |
Flow control can be simulated on the transmission and reception-lines using X-on/off flow control or the control line handshake. |
[ ECHO mode ] |
In the ECHO mode, LE-2100 internally returns received data in units of bits, bytes or frames (character string). It is used to test display terminals and communications terminals, and to set loopback points for the BERT feature. |
[ POLLING mode ] |
The POLLING mode simulates the slave and master units in multidrop(1:N connection) polling protocols. You can easily test complicated POLLING system. |