Interface (standard) | RS-232C (V.24), RS-422/485 (RS-530) | ||||||||||||||||||||||||||||||||||||||||||||
Interface (optional) | X.20/21, RS-499, V.35, current loop, 3V/5V TTL, I2C, IrDA port, CAN, CAN/LIN, high-speed RS-485/CC-link | ||||||||||||||||||||||||||||||||||||||||||||
Protocol |
|
||||||||||||||||||||||||||||||||||||||||||||
Capture memory |
|
||||||||||||||||||||||||||||||||||||||||||||
Baud speed | Full duplex: Max. 2.048
Mbps Half duplex: Max. 4.000 Mbps (3.5 Mbps if continuous data exceeds 1200 byte.) |
||||||||||||||||||||||||||||||||||||||||||||
Internal clock (bps) | Enables to set
user-defined speed for transmission/reception at the
range from 50 to 4.000Mbps in 4-digit decimal
figures. Setting error : +0.01% and -0.01% or less |
||||||||||||||||||||||||||||||||||||||||||||
Data format | NRZ, NRZI, FM0, FM1, 4PPM, ASK, 4PPM | ||||||||||||||||||||||||||||||||||||||||||||
Data code | ASCII, EBCDIC, JIS7, JIS8, Baudot, Transcode, IPARS, EBCD, EBCDIK, HEX | ||||||||||||||||||||||||||||||||||||||||||||
Character framing | ASYNC: Data bit (5/6/7/8)
+ parity bit (0/1) + stop bit (1/2) SYNC, BSC: Data bit + parity bit (total 6, 8 bit) HDLC, SDLC, X.25: Data bit (8 bit) |
||||||||||||||||||||||||||||||||||||||||||||
Parity bit | NONE, ODD, EVEN, MARK, SPACE, MP (Multi-processor bit: Shown with aspecial mark) | ||||||||||||||||||||||||||||||||||||||||||||
Multiple-processor bit | Displays 1.0 state of multiple-processor bit as special mark | ||||||||||||||||||||||||||||||||||||||||||||
Bit transmission order | LSB first, MSB first (switchable) | ||||||||||||||||||||||||||||||||||||||||||||
Polarity inversion | NORMAL, INVERT (switchable) | ||||||||||||||||||||||||||||||||||||||||||||
Error check | Parity (ODD, EVEN, MARK, SPACE), framing, break, abort, short frame, BCC (LRC, CRC-6, CRC-12, CRC-16, CRC-ITU-T, FCS-16, FCS-32) | ||||||||||||||||||||||||||||||||||||||||||||
Monitor function | Handles half-duplex and
full-duplex communications.
|
||||||||||||||||||||||||||||||||||||||||||||
Protocol translation display | SDLC(modulo 8/128), ITU-T X.25(modulo 8/128), LAPD, PPP, BSC, IrLAP, I2C | ||||||||||||||||||||||||||||||||||||||||||||
Interface lead status LEDs (2-color LEDs) |
SD, RD, RS (RTS), CS
(CTS), ER (DTR), DR (DSR), CD (DCD), CI, ST1, ST2,
RT RS-232C - Indicates the logic of signals with 3 modes: ON (red), OFF (green), NC (not lighting). Others I/F - Indicates the logic of signals with 2 modes: ON (red), NC (not lighting). |
||||||||||||||||||||||||||||||||||||||||||||
Timer/counter | Interval timer: 2kinds
(Max. 999999, resolution : 100ms, 10ms, 1ms selectable), Universal counter: 2kinds (Max. 999999), Data counter: 1 each for SD and RD (Max. 4294967295) |
||||||||||||||||||||||||||||||||||||||||||||
Trigger function |
|
||||||||||||||||||||||||||||||||||||||||||||
Data search function | Shows the match data at
the top or enumeration display (selectable).
|
||||||||||||||||||||||||||||||||||||||||||||
Monitor condition auto-setting | Protocol, transmission speed (Max. 115.2Kbps), data code, character synchronous, enables to auto-set the measurement conditions such as BCC | ||||||||||||||||||||||||||||||||||||||||||||
Auto run/stop function | Enables measurement to start and end at the specified time at the selected repeating cycle (monthly, daily, hourly). | ||||||||||||||||||||||||||||||||||||||||||||
Power ON auto run function | Enables measurement to start automatically after power is turned ON. | ||||||||||||||||||||||||||||||||||||||||||||
Auto save function | Enable to auto-save data
in the capture memory, which is being monitored, as log
file onto a memory card. File size: BUF (capture memory size), 1M, 2M, 4M, 8M MAX. files: 1024 |
||||||||||||||||||||||||||||||||||||||||||||
Delay time measurement | Measures and displays the time between changes of interface signal lines (resolution 0.1ms) | ||||||||||||||||||||||||||||||||||||||||||||
Statistical analysis function | Statistics (no. of exchanged characters, no. of frames, no. of satisfied trigger conditions) are collected and displayed in graphs at the range from 1 to 240min. (unit: 1min.) | ||||||||||||||||||||||||||||||||||||||||||||
Logic analyzer | Sampling clock: 1KHZ to
20MHz (14 steps) Sampling memory: min. 2000 sampling Trigger: matching the signal line and logic state of the external signal Trigger position: before, center, after Scale-up/down: *16, *8, *4, *2, *1, *1/2, *1/4, *1/8, *1/16, *1/32, *1/64 Time measurement by the cursor, exchange the signal lines, search a signal state |
||||||||||||||||||||||||||||||||||||||||||||
Bit error rate test | Measures error rate
conforming to ITU-T Notification G.821 by loop-back test
or interactive test. Measurable in the SYNC/ASYNC mode DTE/DCE pin assignments selectable Max. speed: 2,500Mbps Pattern: 26-1, 29-1, 211-1, MARK, SPACE, ALT, DBL-ALT, 1in4, 1in8, 1in16, 3in2 (Inserts 1-bit or 5-bit error in test pattern by key operation.)
|
||||||||||||||||||||||||||||||||||||||||||||
Simulation function | Enables the transmission test of
user-defined data (DTE/DCE pin assignments
selectable) Transmission data memory: 16k Enables to divide to 16 kinds of the data tables for registration. Enables to register parts of transmission data as error data such as parity error. Enables to preset the interface signal line's change and transmission timing. Enables to control the transmission driver for RS-485. |
||||||||||||||||||||||||||||||||||||||||||||
MANUAL mode | While checking communications condition on the monitor, specified data can be transmitted as pressing the corresponding keys with the transmission trigger function when the trigger conditions are matched. | ||||||||||||||||||||||||||||||||||||||||||||
FLOW mode | Simulates on the transmission and reception-lines using X-on/off flow control or the control line handshake of RTS/CTS. | ||||||||||||||||||||||||||||||||||||||||||||
ECHO mode | Returns reception data by a frame unit after specified response time. | ||||||||||||||||||||||||||||||||||||||||||||
POLLING mode | Simulates on multi-polling protocols (slave/master selectable) | ||||||||||||||||||||||||||||||||||||||||||||
BUFFER mode | Selects transmission or reception, and sends transmitted or received data that has been captured in the buffer memory by the monitor function. | ||||||||||||||||||||||||||||||||||||||||||||
PROGRAM mode | Creates a simulation program according to the
protocol using dedicated commands to test transmission
and reception. |
||||||||||||||||||||||||||||||||||||||||||||
Display | Monochrome LCD, 240 x 64 dot, with backlight | ||||||||||||||||||||||||||||||||||||||||||||
Memory card interface | Supports the dedicated
memory cards for16MB, 64MB, 512MB, 1GB. 2GB, 4GB, 8GB(Flash card) Saves/loads the measurement conditions, capture data, simulation data, the simulation program When using a memory card which can record up to 2GB, you can record to 512 files. When using a memory card which can record 4GB or more, you can record to 1,000 files. |
||||||||||||||||||||||||||||||||||||||||||||
AUX (RS-232C) port | RS-232C, 9600 to
230.4Kbps (6 steps) Data output, remote controls input/output from the external devices, input for updating to firmware, PC link software (LE-PC300G) |
||||||||||||||||||||||||||||||||||||||||||||
Printer interface | Centronics 14 pin; LCD display screen, printing continuous format of measurement data | ||||||||||||||||||||||||||||||||||||||||||||
Power supply | Built-in NiMH battery, AC adapter, DC9V, 1.7A (AC100 to 240V, 50/60Hz) | ||||||||||||||||||||||||||||||||||||||||||||
Battery operating charging time | Operating time: approx.
8hours charging time: approx. 2.5hous |
||||||||||||||||||||||||||||||||||||||||||||
Dimensions |
|
||||||||||||||||||||||||||||||||||||||||||||
Environmental requirement | Temperature range: 0 to
40 degree Celsius (operating) ; -10 to 50 degree Celsius (storage) Humidity : 90%RH or below (no condensation) |
||||||||||||||||||||||||||||||||||||||||||||
Regulatory approvals | CE (EMI : Class A) | ||||||||||||||||||||||||||||||||||||||||||||
Accessories |
|
||||||||||||||||||||||||||||||||||||||||||||
Option |
|