Update
LE-8200A/LE-8200 Version History
Version. 1.21 Jan. 25, 2018
- Corrects the bug that BERT with flow control does not work correctly.
- Corrects the bug that on the analog waveform monitoring although a trigger condition is not established it stops upadating the display of waveform.
- Corrects the bug that a time stamp value in a data saved by auto save is registered rarely in error.
Version. 1.20 Jul. 5, 2017
- Supports 128Gbyte CF card.
- File number limitation for th auto save function has extended up to 2048.
- Corrects the error in which sometimes time stamps does not renewed for PROFIBUS
[ detail ]
Version. 1.19 Feb. 20, 2015
- Corrects the minor bug on waveform editor in PULSGEN mode.(LE-8200A only)
- Adds the remote transmission/reception handling for edited data in PULSGEN mode.(LE-8200A only)
- Adds the remote transmission/reception handling in the expanded simulation tables.
- Corrects the bug that statistic data and BERT data cannot be sent or received using remote function.
(Happens on Version 1.04 or above) - Corrects the minor bugs on the guide message.
* To add the remote handling, LE-PC800G (Ver1.08) is needed.
Version. 1.18 Jan. 6, 2015
- Supports the industrial field bus "PROFIBUS".
- Increases the number of pre-resistered data tables up to 160.(before 16 tables)
- Improves the each modes of simulation function.
[MANUAL Simulation]
Able to send 160 kinds of pre-resistered data.
[FLOW Simulation]
Able to send 160 kinds of pre-resistered data with SEND mode.
[PROGRAM Simulation]
Improves the commands of "SEND TBL", "SEND FRM", "IF TBL", "SEND REG", "SEND KEY", and "SET DV" - Adds RS-485 half-duplex simulation mode.
- Improves the timing of driver auto-control of RS-530(RS-485)
- Improves pasing operation of configuration setting
- Corrects the bug that frame which contains 128byte or more cannot be printed correctly in the frame dump format.
- Corrects the bug that sometimes a part of "SEND DA" is not executed.
[ detail ]
Version. 1.17 Oct. 9, 2014
- Adds the function of turning off the power automatically.
- Displays the unit of idle time and time stamp on the top of print-out data.
- Adds the detailed MODBUS translation display for Power meter.
- Corrects the bug of loading data file with Analog waveform.
[ detail ]
Version. 1.16 May. 15, 2014
- Adds the function of prohibiting simulation and BERT functions.
- Correct the bug on Version1.14 and 1.15.
(Cannot load the file saved on the sub-folder.) - Correct the bug on buffer protection for loading data file.
- Correct the typographic error on error massages.
[ detail ]
Version. 1.15 Apr. 11, 2014
- Correct the bug of display massage.
Version. 1.14 Mar. 18, 2014
- Support 64Gbyte CF card.
- Add an icon for CF card on the list of files.
- Add a function of renaming on the list of files, excepting the extension part. (Shift+F3)
- Change the company name from "LINEEYE co., ltd." to "LINEEYE CO., LTD" in the opening screen.
- Change the display of accessing to the CF card on the top right of the screen.
- Correct the bug that Page size is initialized after rebooting.
- Do not allow to input "0" in the timer/counter.
Version. 1.13 May. 16, 2013
- Add/improve the commands of program simulation.
- Add SEND FRM, WAIT MLT, IF FT, SET MOD, SET AD, SET VS, SET VR, SET PF, SET DP commands
- Improve WAIT FRM, WAIT TM, WAIT KEY, IF REG, SET REG commands.
- Change the operating specification of WAIT CHR, WAIT TRG (Character), WAIT LIN, IF CHR commands, and activating the character trigger on TRIGGER function to be save as conventional model (LE-7200/LE3500 etc.)
- Correct the bug of time stamp on transmission when executing a unique command sequence.
- Correct some minor bugs on INT, WAIT and SET LIN commands.
[ detail ]
Version. 1.12 Jan. 8, 2013
- Correct a bug in Modbus protocol added on last update(V1.11).
- Correct a minor bug of frame translation display and dump display on MODBUS-ASCII.
- Correct a minor bug of printouting the frame translation and dump data on MODBUS-ASCII.
- Able to switch the display (frame translation display and dump display), regardless of ASYNC frame NL setting.
- Correct a minor bug of program editor.
- Change the specification of printouting the HDLC abort frame translation and short frame translation to be same as it displays.
- Correct a bug that analyzer freezes when receiving CONF-REQ and then incorrect CONF-ACK frames in PPP.
- Improve a AR clock extraction circuit to detect the abort of NRZI format on RS-485 HDLC.
- Correct a bug of freezing the master clock during SPI slave simulation, when using OP-SB85/85L.
- Correct a bug of incorrect timing of bit on infrared ASK monitored data when using OP-SB85IR.
Version. 1.11 Oct. 17, 2012
- Support Modbus protocol (Modbus-ASCII, Modbus-RTU)
- Support RTS/CTS flow control for BERT.
- Add information of analyzer in the measured data.
Information of analyzer and date of measurement will be added in front of text conversion data or print-out data. - Improve timing of accessing to the CF card.
- Reverse the position of "NS" and "NR"in the title of LrLAP text conversion.
- Correct the bug that data includes ITB character are not added (BCC) by table editor.
- Correct the bug that "P-Type:DIAG" is displayed as "PR:7" by X.25 packet translation display.
- Correct a minor bug of starting transmission of sequential trigger.
- Correct a minor bug of program editor for PROGRAM mode.
- Correct a minor bug of remote monitor.
[ detail ]
Version. 1.10 Apr. 2, 2012
- Support 32G byte CF card.
- Add time stamp unit.
Select "Extend: On" to select "Year/Mon/Day/Hr/Min", "Mon/Day/Hr/Min/Sec", or "Day/Hr/Min/Sec/10ms".
Select "Extend: Off" to select "Day/Hr/Min", "Hr/Min/Sec" or "Min/Sec/10ms". - Add a break transmission function for ASYNC simulation.
- Add "Stop" in the "BT RUN lock" in the system menu.
- Improve AR clock extracted circuit of HDLC NRZI format.
- Improve the driver control AUTO in the RS-485 DTE simulation. It is able to select "ST1" or "RT" clock.
- Correct the minor bug of BSC translation.
- Correct the bug of sending "WAIT" command before completing transmission of "SEND" in the PROGRAM simulation.
- Correct the bug of trigger "send" command, pausing because of response time setting.
The trigger "send" command should not be executed when the measurement stops. - Change the initial setting of time stamp from "OFF" to "HMS".
[ detail ]
Version. 1.09 Oct. 27, 2011
- Support sampling speed up to 100MHz in the Wave Monitor function.
- Add precessing speed (minute, second) in the TREND function.
- Support output and save the measured data in Text format. Furthermore, you can use the measured data in the calculation software etc.
- Support Bit sequence at LSB First (SPI protocol) when using TTL/I2C/SPI expansion board (OP-SB85).
- Able to transmit data when Clock phase is “0” without SS signal at SPI simulation.
- Set back the SDO signal to be “1” when there is a rising edge of SS signal or another clock after transmission of the last bit at SPI Slave simulation.
- Correct the bug of data missing after transmitting 3.7Mbps or more data at ASYNC communication.
[ detail ]
Version. 1.08 Sep. 10, 2010
- Able to measure the HDLC/SDLC data of Manchester code.
- Correct the bug of mis-counting the date of timestamp when measuring data for a couple months.
- Correct the bug of auto-saving. When there is not enough capacity in the CF card, there will be some corrupt auto-saving files and become error.
- Correct the bug that analyzer cannot measure frames when HDLC/SDLC starting flag is also used as ending flag.
- Correct the bug that configuration speed of RD is applied to the SD speed, when setting the STS clock at the DCE simulation.
- Correct the bug that analyzer measure data in duplicate when full duplex.
- Correct the guide message in Enlighsh. "1:Stop" is changed to "1:Count"
at "Action" of the Data Retrieval function.
[ detail ]
Version. 1.07 Apr. 12, 2010
- Add the function which makes the external triger output active.
- Add the settings for "OP-SB85L" in the "INTERFACE" setting menu.
- Add the speed of 50Kbps, 200Kbps, 417Kbps for I2C master simulation.
- Correct the bug of incomplete bit in the SPI slave simulation.
- Change the beginning point to start the SPI slave simulation repeat mode as CS falling.
- Improve the ability when receiving the large amount of data.
- Correct the bug of Flow Simulation Send mode.
- Support high speed access to the CF card.
- Add the inter lock for starting measurement when TTL/IrDA pots are not connected.
- Strengthen the self-check function.
- Correct the miner bug of firmware loader.
[ detail ]
Version. 1.06 Nov. 11, 2009
- Display frame for each timestamp in the new line when ASYNC protocol.
Create a new setting, "ASYNC frame NL" in the Display Control for above condition. - Change the guide message of "Line state" in the Display Control.
- Support "print out" function for displaying timestamp between two frames when HDLC/PPP protocol.
- Add the continuous display of analog waveform when using OP-SB85, OP-SB85IR or OP-SB85C.
(real time waveform while measuring which is similar to the oscilloscopes.) - Add slow sampling clock for analog waveform function.)
( Add 2us, 5us, 10us, 20us, 50us, 100us, 200us, 500us, 1ms ) - Change the position when increasing/decreasing the waveform of analog/logic analyzer display.
- Correct a miner bug of position of cursor/ marker for logic analyzer display.
- Correct a miner bug of I2C translation display.(when using OP-SB85)
- Add a function to communicate with PC efficiently by compressing the simulation program.
- Correct a problem of "Invert"(Interface configuration) for simulation.
- Correct the remote processing for unexpected command/ data.
- Add a fuction not to freeze when receiving a large amount data.
[ detail ]
Version. 1.05 Jul. 8, 2009
- Add the function of User defined translation function in which users can translate frame data at specified position to the characters or numbers.
- Improve the ASYNC “Frame end code” until maximum two characters (“don’t care” is available).
Therefore, users can divide the frame by CR(6Dh) or LF(0Ah), and add the time stamp for 1 character by specifying “don’t care”. - Improve the processing speed of RS-485 driver control when RS-530 driver is “Auto”.
- Correct the bug of processing the communication condition for Auto-configuration.
- Correct the bug of freezing when stopping the Auto-configuration.
- Adjust the timing of I2C stop condition when using OP-SB85.
- Correct the bug of display massage.
[ detail ]
Version. 1.04 Dec. 17, 2008
Bug Fixes
[ detail ]
Version. 1.00 Sep. 10, 2008
LE-8200 released